<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Chauffage &#8211; esa@1410</title>
	<atom:link href="https://e1410.be/category/domotic/chauffage-domotic/feed/" rel="self" type="application/rss+xml" />
	<link>https://e1410.be</link>
	<description>You&#039;re only here for a short visit. Don&#039;t hurry, don&#039;t worry. And be sure to smell flowers along the way</description>
	<lastBuildDate>Sun, 20 Jul 2025 09:55:09 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.4</generator>

<image>
	<url>https://e1410.be/wp-content/uploads/2023/12/cropped-20210600-VresseSurSemois-20210627-111524-32x32.jpg</url>
	<title>Chauffage &#8211; esa@1410</title>
	<link>https://e1410.be</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>A38-Energie-ChaudièreVaillant-EcotecPlus-Condensation</title>
		<link>https://e1410.be/2025/07/20/a38-energie-chaudierevaillant-ecotecplus-condensation/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Sun, 20 Jul 2025 09:55:09 +0000</pubDate>
				<category><![CDATA[Chauffage]]></category>
		<category><![CDATA[domotic]]></category>
		<guid isPermaLink="false">https://e1410.be/?p=8820</guid>

					<description><![CDATA[A38-Energie-Chauffage-2024 1 Comparaison du mois de novembre 2023&#60;&#62; 2024 2 2 Comparaison d&#8217;une température de nuit à 16°C vs 18 °C 4 2.1 Réglage de la t° de consigne de nuit à 16°C 4 2.1.1 Le bureau 4 2.1.2 Le salon 5 2.2 Réglage de la t° de consigne de nuit à 18°C 5 2.3 [&#8230;]]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph"></p>


<p>A38-Energie-Chauffage-2024</p>
<p><a href="#post-8820-_Toc203900487">1 Comparaison du mois de novembre 2023&lt;&gt; 2024 2</a></p>
<p><a href="#post-8820-_Toc203900488">2 Comparaison d&rsquo;une température de nuit à 16°C vs 18 °C 4</a></p>
<p><a href="#post-8820-_Toc203900489">2.1 Réglage de la t° de consigne de nuit à 16°C 4</a></p>
<p><a href="#post-8820-_Toc203900490">2.1.1 Le bureau 4</a></p>
<p><a href="#post-8820-_Toc203900491">2.1.2 Le salon 5</a></p>
<p><a href="#post-8820-_Toc203900492">2.2 Réglage de la t° de consigne de nuit à 18°C 5</a></p>
<p><a href="#post-8820-_Toc203900493">2.3 Type de demande de chaud et réaction de la chaudière. 6</a></p>
<p><a href="#post-8820-_Toc203900494">2.4 Consommation de gaz après la chauffe du matin à même t° des pièces. 7</a></p>
<p><a href="#post-8820-_Toc203900495">2.5 Conclusion. 7</a></p>
<p><a href="#post-8820-_Toc203900496">3 Consommation en fonction de la demande du thermostat. 8</a></p>
<p><a href="#post-8820-_Toc203900497">3.1 Conclusion 8</a></p>
<p><a href="#post-8820-_Toc203900498">4 Chute de t° de nuit 9</a></p>
<p><a href="#post-8820-_Toc203900499">5 Chauffage au bois 10</a></p>
<p><a href="#post-8820-_Toc203900500">5.1 Hivers 2023 10</a></p>
<p><a href="#post-8820-_Toc203900501">6 Comparaison Chaudière StRoch&lt;&gt;Vaillant 11</a></p>
<p><a href="#post-8820-_Toc203900502">6.1 Chaudière st Roch 11</a></p>
<p><a href="#post-8820-_Toc203900503">6.2 Chaudière vaillant 11</a></p>
<p><a href="#post-8820-_Toc203900504">7 Réglage thermostat : impulsion et cycle 12</a></p>
<p><a href="#post-8820-_Toc203900505">7.1 Largeur d&rsquo;impulsion thermostat 12</a></p>
<p><a href="#post-8820-_Toc203900506">7.2 Nombre de cycles 9 / heures 15</a></p>
<p><a href="#post-8820-_Toc203900507">7.3 Nombre de cycles 6 / heures 16</a></p>
<p><a href="#post-8820-_Toc203900508">7.4 Nombre de cycles 3 / heures 19</a></p>
<h1><a id="post-8820-_Toc203900487"></a>Comparaison du mois de novembre 2023&lt;&gt; 2024</h1>
<p>En novembre 2023, le salon est resté très froid avec des t° de 14°C. J&rsquo;ai surtout chauffé au bois pour remonter les t°</p>
<p><img width="506" height="505" class="wp-image-8821"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-1.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-1.png 506w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-1-150x150.png 150w" sizes="auto, (max-width: 506px) 100vw, 506px" /></p>
<p>Ma consommation de gaz : +/- 1000 kWh</p>
<p><img width="1600" height="734" class="wp-image-8822"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-2.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-2.png 1600w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-2-768x352.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-2-1536x705.png 1536w" sizes="auto, (max-width: 1600px) 100vw, 1600px" /></p>
<p>En 2024 : j&rsquo;ai gardé un minimum de 16°C la nuit et 18°C la journée.</p>
<p><img width="507" height="564" class="wp-image-8823"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-3.png"></p>
<p>Consommation de 1300 kWh : soit 30 % en plus pour garder 16 à 18 °C.</p>
<p><img width="1610" height="758" class="wp-image-8824"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-4.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-4.png 1610w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-4-768x362.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-4-1536x723.png 1536w" sizes="auto, (max-width: 1610px) 100vw, 1610px" /></p>
<h1><a id="post-8820-_Toc203900488"></a>Comparaison d&rsquo;une température de nuit à 16°C vs 18 °C</h1>
<p>Le but est d&rsquo;analyser la différence de consommation entre deux t° de nuit différentes et si cela vaut la peine de diminuer le thermostat de 2°C la nuit.</p>
<p>Autrement dit, faut-il garder la t° de nuit à 18°C avec des petites relances de chauffage ou préférer une demande de chaud plus importante à 8:00 pour ramener le t° à 18°C ?</p>
<h2><a id="post-8820-_Toc203900489"></a>Réglage de la t° de consigne de nuit à 16°C</h2>
<p>Le thermostat EvoHome est intégré à HA et permet d&rsquo;analyser les différents paramètres pour chaque pièce.</p>
<h3><a id="post-8820-_Toc203900490"></a>Le bureau</h3>
<p>Exemple du bureau : sur ce graphique, on peut voir :</p>
<ul>
<li>Ligne bleue : la t° de la pièce</li>
<li>Ligne jaune : la demande de t° (thermostat)</li>
<li>Partie pleine : demande de chaud</li>
</ul>
<p>Les nuits précédentes, le thermostat était réglé sur 16°C pour la nuit.</p>
<p>Concernant le bureau, on perd 22°C-16°C = 6°C sur 10 heures (+/- 0.5°C / h).</p>
<p><img width="1762" height="546" class="wp-image-8825"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-5.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-5.png 1762w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-5-768x238.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-5-1536x476.png 1536w" sizes="auto, (max-width: 1762px) 100vw, 1762px" /></p>
<p>Le 25/12, j&rsquo;ai modifié la t° de nuit à 18°C :</p>
<p><img width="1661" height="550" class="wp-image-8826"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-6.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-6.png 1661w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-6-768x254.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-6-1536x509.png 1536w" sizes="auto, (max-width: 1661px) 100vw, 1661px" /></p>
<h3><a id="post-8820-_Toc203900491"></a>Le salon</h3>
<p>Comme je n&rsquo;utilise pas le salon de la journée, la température est réglée à 18°C et baissée à 16°C la nuit.</p>
<p>Durant le nuit, la t° de 16°C doit être maintenue par de légères chauffes pour maintenir le 16°C.</p>
<p>Sinon, cela descendra encore plus bas la nuit et ce n&rsquo;est pas une bonne idée.</p>
<p><img width="1650" height="639" class="wp-image-8827"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-7.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-7.png 1650w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-7-768x297.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-7-1536x595.png 1536w" sizes="auto, (max-width: 1650px) 100vw, 1650px" /></p>
<h2><a id="post-8820-_Toc203900492"></a>Réglage de la t° de consigne de nuit à 18°C</h2>
<ul>
<li>Bureau : la demande de chaud pour maintenir le petit bureau est très limitée.</li>
<li>Salon : La demande de chaud est nécessaire toute la nuit. Sur le graphique, cela est représenté par la couleur « orange claire ».<br /><br />Comparé à 16°C, il y a une grosse différence.</li>
</ul>
<p><img width="1654" height="669" class="wp-image-8828"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-8.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-8.png 1654w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-8-768x311.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-8-1536x621.png 1536w" sizes="auto, (max-width: 1654px) 100vw, 1654px" /></p>
<p>Pour maintenir 18°C, la consommation de minuit au lendemain à 8:00 devrait être plus grande.</p>
<p>Ce qui est bien la cas :</p>
<ul>
<li>Le 23/12 8:00 : 1.4 m³</li>
<li>Le 24/12 8:00 : 1.4 m³</li>
<li>Le 25/12 8:00 : 1.6 m³</li>
</ul>
<p>C&rsquo;est effectivement plus élevé, mais pas tant que cela, car la nuit, la chaudière chauffe avec des petites reprises et à très basse t° (voir explication ci-dessous).</p>
<h2><a id="post-8820-_Toc203900493"></a>Type de demande de chaud et réaction de la chaudière.</h2>
<p>En analysant le fonctionnement de la chaudière, on constate :</p>
<ul>
<li>La nuit du 25/12 <strong>à 18°C</strong> : il n&rsquo;y a jamais de grosse demande et la modulation reste en dessous de 20%. La nuit, il y de nombreuses demandes de chaud chaque 10 minutes à 20 % de modulation.<br /><br />La t° de départ reste bien en dessous de 40°C.</li>
<li><strong>Cercles oranges</strong> : la nuit du 24/12 <strong>à 16°C</strong> : on peut voir de plus grande demande de chaud pour ramener la t° à 16°C. Il y a moins de demande, mais la modulation monte à 80%.<br /><br />Donc, moins de mise en route, mais plus grosse demande d&rsquo;énergie.</li>
<li><strong>Cercles bleus</strong> : le 24/12 à 8:00, il faudra ramener la t° des deux pièces à 18°C.<br /><br />Le matin du 24/12 à 8:00, il y a plus grosse demande de chaud avec une t° de départ à 50°C.</li>
</ul>
<p><img width="1684" height="783" class="wp-image-8829"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-9.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-9.png 1684w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-9-768x357.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-9-1536x714.png 1536w" sizes="auto, (max-width: 1684px) 100vw, 1684px" /></p>
<h2><a id="post-8820-_Toc203900494"></a>Consommation de gaz après la chauffe du matin à même t° des pièces.</h2>
<p>Il faut se mettre dans les mêmes conditions de t° après 8:00 lorsque le thermostat du salon et du bureau remonte à 18°C pour le 24/12 et le 25/12.</p>
<p>La 24/12, la demande de chaud à 8:00 pour remonter la t° de 16°C à 18°C est plus grande (cercles bleus).</p>
<p>La consommation <strong>totale</strong> nuit et chauffe du matin pour arriver à la même t° des pièces :</p>
<ul>
<li>Le 23/12 10:00 : 2.2 m³</li>
<li>Le 24/12 10:00 : 2.2 m³</li>
<li>Le 25/12 10:20 : 2.4 m³</li>
</ul>
<p><img width="1710" height="871" class="wp-image-8830"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-10.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-10.png 1710w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-10-768x391.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-10-1536x782.png 1536w" sizes="auto, (max-width: 1710px) 100vw, 1710px" /></p>
<h2><a id="post-8820-_Toc203900495"></a>Conclusion.</h2>
<p>Je m&rsquo;attendais à avoir une consommation plus élevée en ayant maintenu 18°C au lieu de 16°C.</p>
<p>Le fait de maintenir 18°C, il n&rsquo;y a pas de différences flagrantes en consommation.</p>
<p>Le fait de faire des petites demandes consomme moins (avec petite t° de départ) pour maintenir une t° de nuit plus haute et demandera une moins grande quantité d&rsquo;énergie le matin (voir l&rsquo;analyse ci-dessous).</p>
<h1><a id="post-8820-_Toc203900496"></a>Consommation en fonction de la demande du thermostat.</h1>
<p>Avec des petites demandes (petites impulsions), la t° de la pièce est maintenue avec une t° de départ &lt; 40°C (petite consommation)</p>
<p><img width="1741" height="627" class="wp-image-8831"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-11.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-11.png 1741w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-11-768x277.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-11-1536x553.png 1536w" sizes="auto, (max-width: 1741px) 100vw, 1741px" /></p>
<p>Consommation de gaz horaire :</p>
<p><img width="1668" height="261" class="wp-image-8832"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-12.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-12.png 1668w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-12-768x120.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-12-1536x240.png 1536w" sizes="auto, (max-width: 1668px) 100vw, 1668px" /></p>
<h2><a id="post-8820-_Toc203900497"></a>Conclusion</h2>
<p>Petite demande = +/- 0.3 m³/h</p>
<p>Grande demande = +/- 1 m³/h</p>
<p>Je m&rsquo;attendais à avoir une plus grande consommation de gaz pour une grande demande et une t° de départ de 50°C en sortie.</p>
<p>Voyons cela : de 12:45 à 13:10 = 0.4 m³/25 minutes 🡺 1 m³/h</p>
<p>En toute logique, il y a donc bien une grande différence de consommation / h.</p>
<p><strong>En conclusion : </strong></p>
<p>Il vaut mieux maintenir une t° de la pièce la nuit afin d&rsquo;éviter une grande demande de chaud le matin, car la différence de consommation totale en énergie n&rsquo;est pas significative.</p>
<h1><a id="post-8820-_Toc203900498"></a>Chute de t° de nuit</h1>
<p><img width="1642" height="438" class="wp-image-8833"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-13.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-13.png 1642w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-13-768x205.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-13-1536x410.png 1536w" sizes="auto, (max-width: 1642px) 100vw, 1642px" /></p>
<h1><a id="post-8820-_Toc203900499"></a>Chauffage au bois</h1>
<h2><a id="post-8820-_Toc203900500"></a>Hivers 2023</h2>
<p>Cet hiver 2023 a été bien froid.</p>
<p>J&rsquo;ai pu analyser les consommations en quantité de bois nécessaire pour le chauffage et de gaz.</p>
<p>Avantages :</p>
<ul>
<li>Lorsque les t° extérieures sont négatives, le chauffage au bois est très efficace pour remonter la t° de toute la maison tout en diminuant la consommation de gaz.</li>
<li>Grande production de chaleur avec une t° en journée de 20°C à 25°C (dépend des pièces). Dans le salon, il fait même trop chaud avec des pointes le soir à plus de 25°C.</li>
<li>Diminution de la consommation de gaz.</li>
<li>Amélioration du confort et de la sensation de chaleur.</li>
</ul>
<p>Inconvénients et contraintes :</p>
<ul>
<li>Manutention du bois chaque jour. Il faut remonter le bois de la cave au salon. Une caisse de bois pèse +/- 30 kg. Il en faudra de 3 à 6 caisses.</li>
<li>Il faut +/- 45 minutes de préparation pour la première chauffe du matin. Nettoyage, charge.</li>
<li>Il faut attendre +/- 1 heure avant que le feu produise assez de chaleur.</li>
<li>Il faut recharger régulièrement : toute les une à deux heures. Cela demande une présence à la maison.</li>
<li>Besoin d&rsquo;un espace de rangement au sec à l&rsquo;intérieur (cave). Le bois entreposé à l&rsquo;extérieur, même sous abris ne sera jamais assez sec.</li>
<li>Il faut se procurer le bois en été. C&rsquo;est un gros travail et presque impossible à faire seul. J&rsquo;ai rempli 7 remorques et trois jours de travail.</li>
<li>Ensuite, il faut encore couper et fendre le bois. Besoin de machines adéquates (tronçonneuse, fendeuse, hache) et risque de blessures.</li>
</ul>
<p>En conclusion, je pense toujours utiliser le chauffage au bois lorsque les t° sont inférieures à 5°C, car il y a vraiment un plus au niveau confort tout en diminuant la consommation de gaz.</p>
<p>Au dessus de 10 °C, pour des raisons de facilité mais aussi de quantités à de bois à stocker, je préfère utiliser le chauffage au gaz bien plus pratique.</p>
<p><img width="1600" height="647" class="wp-image-8834"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-14.jpeg" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-14.jpeg 1600w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-14-768x311.jpeg 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-14-1536x621.jpeg 1536w" sizes="auto, (max-width: 1600px) 100vw, 1600px" /></p>
<h1><a id="post-8820-_Toc203900501"></a>Comparaison Chaudière StRoch&lt;&gt;Vaillant</h1>
<p>Comparaison d&rsquo;une chaudière atmosphérique et à condensation pour maintenir une t° la nuit :</p>
<h2><a id="post-8820-_Toc203900502"></a>Chaudière st Roch</h2>
<p><img width="1652" height="793" class="wp-image-8835"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-15.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-15.png 1652w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-15-768x369.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-15-1536x737.png 1536w" sizes="auto, (max-width: 1652px) 100vw, 1652px" /></p>
<h2><a id="post-8820-_Toc203900503"></a>Chaudière vaillant</h2>
<p>A faire</p>
<h1><a id="post-8820-_Toc203900504"></a>Réglage thermostat : impulsion et cycle</h1>
<h2><a id="post-8820-_Toc203900505"></a>Largeur d&rsquo;impulsion thermostat</h2>
<p>Lorsqu&rsquo;il y a une demande de chaud, le thermostat fournit une impulsion à la chaudière.</p>
<ul>
<li>Impulsion de 5 minutes : j&rsquo;avais réglé une larguer minimum d&rsquo;impulsion de 5 min.<br /><br />Ce qui me semble de trop, puisque la t° de départ augmente régulièrement à chaque cycle de 10 minutes pour maintenir la t° du salon à 18°C (demande &lt; 20%).</li>
<li>Impulsion de 1 minute : la t° de départ diminue de trop.</li>
<li>Impulsion de 2 minutes : la t° de départ augment modérément.</li>
</ul>
<p>Il faut régler l&rsquo;impulsion minimum afin de permettre une meilleure modulation de la chaudière et ne pas demander trop d&rsquo;énergie à chaque demande.</p>
<p>Si ce n&rsquo;est pas assez, le thermostat va augmenter sa largeur d&rsquo;impulsion automatiquement 🡺 mais, ce n&rsquo;est pas la cas lorsque la t° ambiante est proche de la consigne (voir plus bas).</p>
<p>Une minimum de largeur d&rsquo;impulsion de 2 min me semble plus correct.</p>
<p><img width="1357" height="626" class="wp-image-8836"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-16.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-16.png 1357w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-16-768x354.png 768w" sizes="auto, (max-width: 1357px) 100vw, 1357px" /></p>
<p>Finalement, le thermostat a rallongé les impulsions à +/- 5 minutes :</p>
<p><img width="302" height="529" class="wp-image-8837"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-17.png"></p>
<p>La régulation se fait avec une stabilisation de la t° de départ autour des 40 °C.</p>
<p>Lorsqu&rsquo;il y a une demande plus grande, la t° de la chaudière monte au dessus de la consigne de 45°C et se coupe par une protection interne.</p>
<p>Le circulateur continue à tourner +/- 10 minutes.</p>
<p>La chaudière se remet en route une fois la t° de départ à 30°C. Ce n&rsquo;est pas l&rsquo;idéal.</p>
<p><img width="706" height="610" class="wp-image-8838"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-18.png"></p>
<p>Pourtant, la modulation de la puissance n&rsquo;est pas montée à plus de 40 %</p>
<p><img width="525" height="445" class="wp-image-8839"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-19.png"></p>
<h2><a id="post-8820-_Toc203900506"></a>Nombre de cycles 9 / heures</h2>
<p>J&rsquo;ai augmenté le nombre de cycle à 9 par heure.</p>
<p>La nuit, la consigne est de 19°C dans la chambre et la t° ambiante n&rsquo;a jamais dépassé les 18°C.</p>
<p>La t° de départ diminue progressivement vers les 30°C.</p>
<p>Je pense que les impulsions sont trop courtes avec un cycle de 7 minutes : impulsion de +/- 3 minutes chauffe + 4 minutes d&rsquo;arrêt.</p>
<p><strong>Mais pourquoi le thermostat n&rsquo;augmente pas spontanément la demande de chaud et donc la longueur de pulse ?</strong></p>
<p>Je suis remonté à un minimum de pulses de 4 minutes et 6 cycles par heures.</p>
<p><img width="667" height="616" class="wp-image-8840"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-20.png"></p>
<h2><a id="post-8820-_Toc203900507"></a>Nombre de cycles 6 / heures</h2>
<p>Avec un nombre de cycle programmé à 6 / heures, je n&rsquo;arrive pas à maintenir une t°.</p>
<p>Lorsqu&rsquo;il y a une demande forte, le pulse est plus grand et la t° monte assez vite.</p>
<p>Mais la nuit, la t° n&rsquo;arrive jamais à la consigne :</p>
<p><img width="1556" height="627" class="wp-image-8841"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-21.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-21.png 1556w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-21-768x309.png 768w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-21-1536x619.png 1536w" sizes="auto, (max-width: 1556px) 100vw, 1556px" /></p>
<p>Il y a une demande de +/- 25 % pour la chambre et +/- 15 % pour le living. Mais la modulation de la chaudière ne monte jamais.</p>
<p><img width="1409" height="439" class="wp-image-8842"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-22.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-22.png 1409w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-22-768x239.png 768w" sizes="auto, (max-width: 1409px) 100vw, 1409px" /><br /><img width="796" height="531" class="wp-image-8843"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-23.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-23.png 796w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-23-768x512.png 768w" sizes="auto, (max-width: 796px) 100vw, 796px" /></p>
<p>Le bureau est bien maintenu à la t° de consigne : j suppose qu&rsquo;il faut moins d&rsquo;énergie (PC + petite pièce).</p>
<p><img width="1008" height="466" class="wp-image-8844"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-24.png" srcset="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-24.png 1008w, https://e1410.be/wp-content/uploads/2025/07/word-image-8820-24-768x355.png 768w" sizes="auto, (max-width: 1008px) 100vw, 1008px" /></p>
<p>Pour la chambre :</p>
<ul>
<li>En rouge : A chaque fois qu&rsquo;il y a une grande demande (t° fortement différente avec la consigne), la longueur d&rsquo;impulsion augmente et la chaudière réagi.</li>
<li>En bleu : la t° n&rsquo;est pas à la consigne, mais juste en dessous et la modulation du thermostat ne monte pas. Dès lors, la t° n&rsquo;atteint jamais la consigne.</li>
</ul>
<p><img width="660" height="809" class="wp-image-8845"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-25.png"></p>
<p>Pourquoi EvoHome n&rsquo;augmente pas la longueur des impulsions (ou la % de demande) lorsque la t° est proche, mais <strong>en dessous</strong> de la consigne ?</p>
<p>J&rsquo;ai deux possibilités :</p>
<ul>
<li>Rallonger les pulse par diminution du nombre de cycles. J&rsquo;ai programmé le nombre de cycles à 3/h.</li>
<li>Rallonger les impulsions minimum à plus de 5 minutes.</li>
</ul>
<h2><a id="post-8820-_Toc203900508"></a>Nombre de cycles 3 / heures</h2>
<p>A 11:30, plus de chauffe pendant une heure ! J&rsquo;ai donc une impression de froid alors que la t° de mon bureau est à 20°C.</p>
<p><img width="754" height="610" class="wp-image-8846"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-26.png"></p>
<p>Mais pourquoi attendre que la t° repasse en dessous de la consigne de 21°C et à 20°C, toujours pas de remise en service ?</p>
<p><img width="297" height="396" class="wp-image-8847"  / loading="lazy" decoding="async" src="https://e1410.be/wp-content/uploads/2025/07/word-image-8820-27.png"></p>
<p>J&rsquo;ai donc élevé la consigne à 22°C.</p>
<p>Lorsque la t° dépasse la consigne, il faut attendre trop longtemps. Je repasse donc en 6 cycles par heures.</p>]]></content:encoded>
					
		
		